TH-G506-4E2SFP Smart Industrial Ethernet Suiga

Numera Fa'ata'ita'iga:TH-G506-4E2SFP

Fa'ailoga:Todahika

  • O le DIP Switch e lagolagoina le RSTP/VLAN/SPEED
  • Lagolago le IEEE802.3az fa'atekonolosi Ethernet e fa'aogaina le malosi

Fa'amatalaga Oloa

Vaega

Fa'amatalaga Fa'atonu

Fa'amatalaga

Fua

Faailoga o oloa

Fa'amatalaga o oloa

TH-G506-4E2SFP o se augatupulaga fou Industrial Managed Power over Ethernet Switch ma le 4-Port 10/100/1000Base-TX PoE ma le 2-Port 100/1000 Base-FX Fast SFP lea e faʻaalia ai 4 Gigabit Ethernet ports e lagolagoina PoE, faʻatagaina mo le eletise ma faʻamatalaga faʻasalalauga o masini fesoʻotaʻi e pei o IP kamera, laina avanoa e leai se fesoʻotaʻiga, ma telefoni VoIP.

O lenei mea e faʻaumatia ai le manaʻoga mo sapalai eletise eseese ma faʻafaigofie le faʻapipiʻiina, faʻapea foʻi ma ports 2 Fast SFP e lagolagoina le faʻaliliuina o faʻamatalaga e oʻo atu i le 100Mbps poʻo le 1000Mbps.

TH-8G0024M2P

  • Muamua:
  • Sosoo ai:

  • ● 4×10/100/1000Base-TX PoE RJ45 ports, 2×100/1000Base-FX Vave SFP ports

    ● DIP Switch e lagolagoina le RSTP/VLAN/SPEED.

    ● Lagolago le 9K bytes jumbo frame, fetaui ma faʻasalalauga faʻaopoopoga eseese

    ● Lagolago le IEEE802.3az fa'atekonolosi Ethernet e fa'aleleia le malosi

    ● Eletise 4KV surge puipuiga, faigofie ona faaaoga i se siosiomaga i fafo

    ● mamanu puipuia polarity ulufale Power

    Igoa Fa'ata'ita'iga Fa'amatalaga
    TH-G506-2SFP 4×10/100/1000Base-TX RJ45 ports, 2×100/1000Base-FX SFP ports with DIP Switch, voltage input 956VDC
    TH-G506-4E2SFP 4×10/100/1000Base-TX POE RJ45 ports, 2×100/1000Base-FX SFP ports with DIP Switch, voltage input 4856VDC
    Feso'ota'iga Ethernet
    Taulaga 4×10/100/1000BASE-TX POE RJ45, 2x1000BASE-X SFP
    Tulaga IEEE 802.3 mo le 10BaseT

    IEEE 802.3u mo 100BaseT(X) ma 100BaseFX

    IEEE 802.3ab mo 1000BaseT(X)

    IEEE 802.3z mo 1000BaseSX/LX/LHX/ZX

    IEEE 802.3x mo le pulea o le tafe

    IEEE 802.1D-2004 mo le Spanning Tree Protocol

    IEEE 802.1w mo le Vave Spanning Tree Protocol

    IEEE 802.1p mo Vasega o Auaunaga

    IEEE 802.1Q mo VLAN Tagging

    Fua Fa'amau o le Peke 2M
    Umi o le afifi 16K
    Laupapa tuatusi MAC 4K
    Faiga Fa'asalalau Teu ma Fa'asaga i luma (tulaga atoa/afa fa'alua)
    Fetufaaiga Meatotino Taimi tuai: <7μs
    Fuafuaga i tua 20Gbps
    POE(faitalia
    Tulaga POE IEEE 802.3af/IEEE 802.3at POE
    taumafa POE O taulaga ta'itasi max 30W
    Malosiaga
    Malosiaga Ulufale Fa'aoga mana lua 9-56VDC mo le POE ma le 48 ~ 56VDC mo POE
    Fa'aaogāga malosi Uta atoa<10W(non-POE); Uta atoa<130W(POE)
    Uiga Faaletino
    Fale pusa alumini
    Fua 120mm x 90mm x 35mm (L x W x H)
    mamafa 350g
    Faiga Fa'apipi'i DIN Rail ma le Faʻamauina o Pa
    Siosiomaga Galuega
    Galulue Vevela -40℃~75℃ (-40 i le 167 ℉)
    Susū Fa'agaioiga 5%~90% (e le fa'asa'o)
    Teuga vevela -40℃~85℃ (-40 i le 185 ℉)
    Fa'amaonia
    MTBF 500000 itula
    Vaitaimi Noataga Fa'aletonu 5 tausaga
    Tulaga Fa'amaonia FCC Vaega15 Vasega A

    CE-EMC/LVD

    ROSH

    IEC 60068-2-27(Te'i

    IEC 60068-2-6(Tetete

    IEC 60068-2-32(Pau fua

    IEC 61000-4-2(ESD):Laasaga 4

    IEC 61000-4-3(RS):Laasaga 4

    IEC 61000-4-2(EFT):Laasaga 4

    IEC 61000-4-2(Si'itia):Laasaga 4

    IEC 61000-4-2(CS):Laasaga 3

    IEC 61000-4-2(PFMP):Laasaga 5

    Galuega Fa'akomepiuta Tasi Ki mo RSTP ON/OFF, VLAN ON/OFF, SFP uafu tumau saoasaoa, ON pei 100M saoasaoa
    Feso'ota'iga Fa'aletonu: STP/RSTP
    Lagolago Telecast: IGMP Snooping V1/V2/V3
    VLAN: IEEE 802.1Q 4K VLAN
    QOS: Taulaga, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA
    Pulega Galuega: WEB
    Tausiga Su'esu'ega: fa'ata o le taulaga, Ping