TH-G506-2SFP Smart Industrial Ethernet Suiga

Numera Fa'ata'ita'iga:TH-G506-2SFP

Fa'ailoga:Todahika

  • Mana fa'asili DC12-58V ma AC100~240V fa'aoga
  • Shell IP40 tulaga puipuia, mamanu e leai se ili

Fa'amatalaga Oloa

Vaega

Fa'amatalaga Fa'atonu

Fa'amatalaga

Fua

Faailoga o oloa

Fa'amatalaga o oloa

TH-G506-2SFP o se fa'atuputelega fou Powered over Ethernet ki fa'atasi ma le 4-Port 10/100/1000Bas-TX ma le 2-Port 100/1000 Base-FX Fast SFP lea e tu'uina atu fa'amaumauga Ethernet fa'alagolago.

E maua ai le fetuunaiga mo ituaiga eseese o fesoʻotaʻiga fesoʻotaʻiga.O lenei ki o loʻo pulea foi, o lona uiga e mafai ona faʻatulagaina ma mataʻituina mo le faʻatinoga lelei.E masani ona lagolagoina vaega faʻapitoa e pei ole VLAN, pulega QoS, ma e mafai foʻi ona lagolagoina faʻasalalauga e pei ole RSTP ma le STP mo le toe faʻaleleia ma vave toe faʻaleleia pe a faʻaletonu fesoʻotaʻiga.

TH-8G0024M2P

  • Muamua:
  • Sosoo ai:

  • ● 4x10/100/1000Base-TX RJ45 ports ma 2x100/1000Base-FX Fast SFP ports switch.O lenei suiga mataʻina o loʻo faʻaalia ai le DIP Switch e lagolagoina le RSTP / VLAN / SPEED, faʻatagaina mo le maualuga o fetuutuunaiga ma faʻapitoa.Faatasi ai ma le lagolago mo le 9K bytes jumbo frame, o lenei ki e fetaui ma faʻasalalauga faʻaopoopoga eseese, ma avea ai ma fofo lelei mo le tele o manaʻoga fesoʻotaiga.

    ● E le gata i lea, o la matou kilia e aofia ai le IEEE802.3az e faʻaogaina le malosi o le Ethernet, faʻamautinoaina le faʻaogaina lelei o le malosi ma faʻaitiitia le aʻafiaga o le siosiomaga.Fuafuaina ma le taulaʻi i le tumau ma le faʻamaoni, o lenei ki o loʻo faʻaalia ai le eletise 4KV surge protection, e talafeagai mo le faʻaogaina i totonu o siosiomaga i fafo e maualuga ai le lamatiaga o le eletise.

    ● E le gata i lea, o la matou oloa e aofia ai se mamanu puipuia o le polarity eletise, e ofoina atu se isi vaega o le saogalemu i le taimi o le faʻapipiʻiina ma le faʻaogaina.O le pusa alumini ma le fa'aitiitiga o le fa'ailoga e mautinoa ai le fa'amama lelei o le vevela

    Igoa Fa'ata'ita'iga Fa'amatalaga
    TH-G506-2SFP 4×10/100/1000Base-TX RJ45 ports, 2×100/1000Base-FX SFP ports with DIP Switch, voltage input 956VDC
    TH-G506-4E2SFP 4×10/100/1000Base-TX POE RJ45 ports, 2×100/1000Base-FX SFP ports with DIP Switch, voltage input 4856VDC
    Feso'ota'iga Ethernet
    Taulaga 4×10/100/1000BASE-TX RJ45, 2x1000BASE-X SFP
    Tulaga IEEE 802.3 mo le 10BaseT

    IEEE 802.3u mo 100BaseT(X) ma 100BaseFX

    IEEE 802.3ab mo 1000BaseT(X)

    IEEE 802.3z mo 1000BaseSX/LX/LHX/ZX

    IEEE 802.3x mo le pulea o le tafe

    IEEE 802.1D-2004 mo le Spanning Tree Protocol

    IEEE 802.1w mo le Vave Spanning Tree Protocol

    IEEE 802.1p mo Vasega o Auaunaga

    IEEE 802.1Q mo VLAN Tagging

    Fua Fa'amau o le Peke 2M
    Umi o le afifi 16K
    Laupapa tuatusi MAC 4K
    Faiga Fa'asalalau Teu ma Fa'asaga i luma (tulaga atoa/afa fa'alua)
    Fetufaaiga Meatotino Taimi tuai: <7μs
    Fuafuaga i tua 20Gbps
    POE(faitalia
    Tulaga POE IEEE 802.3af/IEEE 802.3at POE
    taumafa POE O taulaga ta'itasi max 30W
    Malosiaga
    Malosiaga Ulufale Fa'aoga mana lua 9-56VDC mo le POE ma le 48 ~ 56VDC mo POE
    Fa'aaogāga malosi Uta atoa<10W(non-POE);Uta atoa<130W(POE)
    Uiga Faaletino
    Fale pusa alumini
    Fua 120mm x 90mm x 35mm (L x W x H)
    mamafa 350g
    Faiga Fa'apipi'i DIN Rail ma le Faʻamauina o Pa
    Siosiomaga Galuega
    Galulue Vevela -40℃~75℃ (-40 i le 167 ℉)
    Susū fa'agaioiga 5%~90% (e le fa'asa'o)
    Teuga vevela -40℃~85℃ (-40 i le 185 ℉)
    Fa'amaonia
    MTBF 500000 itula
    Vaitaimi Noataga Fa'aletonu 5 tausaga
    Tulaga Fa'ailoga FCC Vaega15 Vasega A

    CE-EMC/LVD

    ROSH

    IEC 60068-2-27(Te'i

    IEC 60068-2-6(Tetete

    IEC 60068-2-32(Pau fua

    IEC 61000-4-2(ESD):Laasaga 4

    IEC 61000-4-3(RS):Laasaga 4

    IEC 61000-4-2(EFT):Laasaga 4

    IEC 61000-4-2(Si'itia):Laasaga 4

    IEC 61000-4-2(CS):Laasaga 3

    IEC 61000-4-2(PFMP):Laasaga 5

    Galuega Fa'akomepiuta Tasi Ki mo RSTP ON/OFF, VLAN ON/OFF, SFP uafu tumau saoasaoa, ON pei 100M saoasaoa
    Feso'ota'iga Fa'aletonu: STP/RSTP
    Lagolago Telecast: IGMP Snooping V1/V2/V3
    VLAN: IEEE 802.1Q 4K VLAN
    QOS: Taulaga, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA
    Pulega Galuega: WEB
    Tausiga Su'esu'ega: fa'ata o le taulaga, Ping